| Technical Specification-SOL1224-50A |
| General |
| Model |
SOL1224-50A |
| Operating Temperature |
0°C to 50°C |
| Storage Temperature |
-10°C to 60°C |
| System Operating Voltage |
12V/24V DC |
| Battery Type |
Tubular/SMF |
| Battery Capacity Max. |
200AH |
| Battery Charging Regulation Method |
4 Stage PWM (Bulk/Absorption/Float/Equalize) |
| Max. Solar Power |
12V:800WÂ Â Â 24V: 1700W |
| Max. Solar Panel Recommended |
12V, 25A :Â 150W/165W *3 (Parallel) |
| 24V, 25A :Â 250W/315W/325W*3 ( Parallel |
| 12V, 50A : 150W/165W *5 (Parallel) |
| 24V, 50A :Â 250W*6 , 315W/325W*5, 390W/400W/425*4 ( Parallel) |
| Electrical |
| Nominal Grid Voltage |
230V AC 1Φ |
| Grid Low Cut |
90V + 10V |
| Grid High Cut |
290V + 10V |
| Charging Current (Solar) |
50A/25A |
| Charge Controller Efficiency |
40A/20A |
| Idle Consumption |
> 95% |
| Max. Solar input Voltage (Voc) |
<20mA |
| 17V-25V ( 12V Batt.) |
| Min. Solar input voltage (Voc) @ Start-up |
31V-49.5V (24V Batt.) |
| Solar Panel Recovery Voltage |
15V/30V + 2% |
| Max. Solar Current |
17V/34V + 2% |
| Efficiency |
>95% |
| Battery Set Points @ 25°C |
| Bulk Voltage Tubular Battery |
14.6V/29.2V + 2% |
| Absorption Voltage Tubular Battery |
14.2V/28.4V + 2% |
| Float Voltage Tubular Battery |
14V/28V + 2% |
| Bulk Voltage SMF Battery |
13.7V/27.4V + 2% |
| Float Voltage SMF Battery |
13.5V/27.0V + 2% |
| Absorption Duration |
3Hr |
| Equalize Voltage |
14.9V/29.8V + 2% |
| Equalize Duration |
3Hr |
| Equalize calendar |
28 days |
| Mains reconnect when Solar is not present |
At any Batt. Voltage |
| Mains reconnect when insufficient Solar Power |
 < 11.8V/ 23.6V + 2% |
| Mains disconnect when sufficient Solar Power For Tubular |
> 13.8V/27.6V + 2% |
| Mains disconnect when sufficient Solar Power For SMF |
13.7V/27.4VÂ + 2% |
| Display Parameters |
|
| 1. Batt. Voltage, Batt. Current, Batt. Type |
1. Battery Reverse Polarity |
| 2. Solar Voltage, Solar Current |
2. Batt. Reverse Current |
| 3. Mode Selection |
3. Over Current of SPV : >56A/28A |
| 4. Solar Status: High, Low, Overload, Overheat |
4. Solar High Voltage |
| 5. Saving- KWh |
5. SPV Reverse Polarity |
| 6. Mains Present, Low, High, Absent |
6. Load Short Circuit through AC Fuse |
| 7. Max. PV Current |
7. Solar Low Voltage |
|
8. Over Temperature |
| Physical |
| Ingress Protection |
IP-20 |
| Fixing |
Wall Mounted |
| Weight (Kg) |
2.33 |
| Dimension (LXWXH) Inch |
9.6X6.9X4.9 |
| * Specification are subject to change without prior notice due to constant improvement in design & technology. |
Reviews